Specifications

Product Description

Module Diagram

Technical Data and Certifications

The Aurora Roofing Systems offers a straightforward, efficient method of installing both Natural Slate and Aurora Ceramic Tiles.

This incredibly robust system incorporates Zincalume Battens spaced at 307.7mm. Locked in place between the battens are Aurora Link Channels, each possessing a stainless steel clip used for securing the leading edge of each slate.

This Link Channel eliminates the need for side double-lapping of slates because water passing through the slate is routed by the Link Channel onto the surface of the slate below.

Tests Performed on Aurora Ceramic Slate Tiles

Tests performed by CREAM Building Technology Laboratory (UK):

BS EN 538 1994 - Flexural Strength Test
BS EN 539 1994 - Physical Characteristic Impermeability Test
BS EN 539/2 1998 - Frost Resistance Test
BS EN 1024 1997 Geometric Test BS
EN 1304 1998 Product Definition and Specification Test

Test performed by Turin Polytechnic (Italy)

Dept of Geological Resources and Territory:

Water Absorption Resistance to indirect traction by means of bending Resistance to indirect traction by means of bending after freezing Resistance to alterations caused by weatherExternal Fire Exposure

BS 476: Part 3 1958

Simulated Static and Cyclic Wind Uplift Test

Passed Wind Classification up to and including C2 (cyclonic wind test).

Test performed on Aurora Fixing System

AS 2050 1989 Weather Effectiveness of Roofing System Structural

Upwards to ultimate
Upwards to serviceability
Downwards to ultimate
Downwards to serviceability
Florida Building Code Test Protocol TAS100-95 – test procedure for wind and wind-driven rain resistance of discontinuous roof systems.